Embolization Coil System

Embolization Coil System

Renova embolization coil system is a medical device used in neurovascular interventions to treat cerebral aneurysms, which are bulges in the blood vessels in the brain that can potentially rupture and cause a stroke. The Renova cerebral aneurysm coiling is made up of tiny wire coils that are inserted into the aneurysm through a catheter and packed in tightly to prevent blood flow that would otherwise further weaken the vessel wall. The coils are detached from the delivery wire after implantation, creating a scaffold that encourages the formation of a clot which ultimately seals off the aneurysm.

Product Introduction

RenovaTM Embolization Coil System

One of the key features of the RenovaTM embolization coil system is its minimally invasive nature. Unlike open surgery, where a craniotomy is usually required to access the brain, this procedure only requires a small incision in the groin where the catheter is inserted. This leads to faster recovery times and fewer complications, which is especially important for patients who are frail or elderly. Another advantage of this system is its versatility in treating different types of aneurysms. This includes small or wide-necked aneurysms, which can be more challenging to treat with other methods. It also offers significant benefits to neurointerventionists, who are the physicians who perform these procedures. The detachable coils are designed with a unique detachment mechanism that allows for precise control during deployment, which reduces the risk of complications like coil migration or perforation. This also allows for better visualization during the procedure, as the coils can be repositioned or removed as needed.

 

Features&Advantages

1. From frame to finish, various softness levels and sizes cover a variety of cases.

Cerebral Aneurysm Coiling

2. Open loop design minimizes compartmentalization and distributes evenly.

3. The first 1.5 loops 25% smaller than the stated secondary coil diameter reduces risk of coil herniation.

4. Shorter detachment zone greatly minimizes kick-back microcatheter.

Embolization Coil System

5. It frames securely, fills uniformly and finishes by seeking voids within aneurysm.

Endovascular Coiling Aneurysm

FAQ

Q1:Are you a factory or a trade company?

A1: We are the manufacturer, but OEM are available.

Q2: Can I have a sample for testing?

A2: Yes, stock samples are available.

Q3: What is sample ready time?

A3: For the samples in stock, it usually takes 3-5 days. For OEM products, it will take 45 days after all sample’s details confirmed.

 

 

Send Inquiry

whatsapp

skype

E-mail

Inquiry

Bag