Thrombus Aspiration Devices

Thrombus Aspiration Devices

The Glutton TM Thrombus Aspiration Device is designed to offer a balance between crossing performance, kink resistance and thrombus-aspiration capability. It has excellent crossability while providing atraumatic and effective aspiration.

Product Introduction

The Glutton TM Thrombus Aspiration Device is designed for aspiration thrombectomy and offers an ideal combination of excellent distal trackability and a large 0.072" lumen to help with rapid recanalization of the affected vessel. The intracranial thrombus aspiration device with a large lumen, braided structure and hydrophilic coating is a new type of device for thrombus aspiration in the cerebral vessels, which has several advantages over traditional devices. Firstly, the device has a large lumen, which means that it has a wider range of application and can remove thrombus more efficiently. Secondly, the device is made of braided structure/hydrophilic coating, which makes it more flexible and easier to operate during the procedure. This makes the procedure more precise and reduces the probability of complications. Thirdly, the hydrophilic coating makes the device more biocompatible, reduces the risk of adverse reactions, and improves the safety of the procedure. The large lumen of the intracranial thrombus aspiration device allows it to remove thrombus of different sizes and shapes. The device can remove thrombus both proximally and distally, which is important for the complete removal of thrombus. The large lumen also allows the device to be used in different cerebral vessels, such as the anterior cerebral artery, middle cerebral artery, and posterior cerebral artery. This makes the device more versatile and increases its clinical value.

 

Thrombus Aspiration Catheter
Features & Benefits

1. Hybrid coil and braiding technology for increased resistance to kinking and trackability.
Thrombus Aspiration Devices

2. 0.072" larger diameter inner lumen for aspiration to capture large clots from vessels.

3. Great aspiration power and aspiration force help with rapid vessel recanalization.

Access Aspiration Catheter

4. Proximal composite polymer for excellent pushability and control.

5. Hydrophilic coating and smooth catheter transitions allow smooth bypass of difficult bifurcations.

6. Gradual hardness design provides optimal catheter support for precise and uniform deployment of interventional devices.

 

Use For Thrombus Aspiration Devices

The length of Glutton TM Thrombus Aspiration Device is 115-132cm. The inner diameter is 0.072"(1.83mm). There is a soft segment at the distal end. The farthest can reach the end of the internal carotid artery.

 

Specifications
Product Parameter for Aspiration Catheter

FAQ

Q1: What about the payment methods?

A1: T/T, L/C, Paypal, Western Unionare available. USD, EURO and CNY are acceptable.

 

Q2: Can I have a sample for testing?

A2: Yes, stock samples are available.

 

Q3: Can I print our logo on the package?

A3: Yes, we can do custom printing on the package.